Optical88_ZCCMMP
Optical 88 Children Myopia Management Programme(including Axial Length Measurement)
Recommended for
-
Recommended for 4 to 16 years old
Key Checkup Items:
-
By Optometrist (About 75 minutes), Cycloplegic refraction check, Visual acuity, Intra-ocular pressure (IOP) measurement, Binocular vision assessment, Colour vision test, Stereopsis, Slit lamp examination on outer and inner eye structures, Dilated fundus examination, Corneal topography to evaluate the feasibility of Orthokeratology (OK-lens), Axial length measurement(by optical biometry), Trial of Ortho-k Lens
User Reviews
- 1
Eye Check
Highlight-
Corneal Topography
-
Trial of Ortho-k Lens
-
Axial length measurement(by optical biometry)
-
Analysis of risk factors and solutions for myopia management
-
Consultation and recommendation
Eye Check
-
Optometrist Consultation
-
Visual Acuity
-
Intra-ocular pressures
-
Color vision tests
-
Stereopsis
-
Slit lamp examination
-
Dilated fundal examination
-
Digital Retinal Scans
-
Pupillary reflex
-
Internal and External Ocular Health
-
Binocular vision assessment
-
Refraction
Report
-
Report and explanation by Optometrist
Children Myopia Management Programme(including Axial Length Measurement)
- The peak period of myopia progression in Hong Kong children is between the ages of 6-10, which is also the golden ages for learning. Therefore, parents should pay extra attention to the myopia development in children. Appropriate measures should be taken to control myopia progression and ensure healthy vision development.
- Children Myopia Management Programme includes 14 detailed assessments which help to understand the cause of myopia and give recommendation on myopia management. The 4 major myopia management solutions include orthokeratology (known as Ortho-K lens), spectacle lens for myopia management, and soft contact lens for myopia management and atropine eye drops. Optometrist will explain the restrains, pros and cons of each solution.
Important Reminder: Pupil dilation maybe needed during eye exam. We suggest you to put on sunglasses, avoid driving, using computer and reading after eye examination. In general, ocular function will resume normal after 4-6 hours.
Optical 88 Children Myopia Management Programme (including Axial Length Measurement)Included:
1. Case history
Identify poor visual habit and vision problems, evaluate the risk of myopia progression
2. Cyclopedic Refraction check*
Children often with active accommodation. Cyclopedic refraction allows more precise assessment of myopia, hyperopia, astigmatism, etc. This helps to eliminate error caused by pseudo-myopia and give better assessment of refractive errors
3. Visual acuity (VA)
Check the distance and near VA, assess risk of amblyopia and evaluate if vision fulfills the requirement for effective learning
4. Intra-ocular pressure (IOP) measurement
Rise in IOP may result in glaucoma which may lead to blindness if left untreated
5. Binocular vision assessment
Visual function assessment on squint, accommodation (ability in changing focus) and motility (alignment of eyes in tracking target). Binocular vision problems may lead to tired eyes, blurry vision and double vision, which may affect learning
6. Colour vision test
Test on ability to differentiate colors, colour vision problem may affect learning and future career selection
7. Stereopsis (depth perception)
Good stereoacuity is important for precise judgment of distance and three-dimension perception, it is also important for sport performance
8. Slit lamp examination on outer and inner eye structures
Assessment of sensitive eyes (itchiness), corneal health, congenital cataract, etc.
9. Dilated fundus examination (retina image capture with digital fundus camera)
Assessment of the central and peripheral retina, can reveal some severe eye diseases such as retinal tear, glaucoma, diabetic retinopathy and macular degeneration. Digital retinal image is captured for photo documentation
10. Axial Length Measurement (by Optical Biometry)
Axial Length is the distance from the corneal surface to the retinal pigmented epithelium. An axial length of 26mm or greater indicates higher risk of vision threatening eye diseases.
Excessive axial elongation lead to myopia progression, hence controlling axial elongation becomes the key for myopia management
11. Corneal topography
Obtains 3D map of the curvature of cornea to decide if some myopia control treatments, such as Ortho- K lens, soft contact lenses for myopia management, are suitable
12. Analysis of risk factors and solutions for myopia management
Analysis of visual habits, environmental and the genetic factors for myopia progression in children. Detailed explanation on the restrains, pros and cons of each solution for myopia management.
13. Trial of Ortho-K lens
For clients who wish to try Ortho-K lens, optometrist will provide trial to evaluate the corneal response (change in corneal curvature and refractive errors) to Ortho-K lens wear, obtain data for ordering the best fit Ortho-K lens for myopia management programme
14. Consultation and recommendation
Evaluate the risk of myopia progression, give advice on myopia management and good visual habits
Terms and Conditions:
- A confirmation email will be sent to customer immediately after successful payment and Optical 88 will email the e-redemption letter to the registered email address within 2 working days. The customer is required to make an appointment in advance after receiving the e-redemption letter. Please refer to the letter for our centres’ contact information.
- Redemption of hearing examination is only applicable in Optical 88 Hearing Centres in Hong Kong; Redemption of eye examination is only applicable in Optical 88 Professional Eyecare Centres in Hong Kong.
- This e-redemption letter can only be used once.
- Once the order is confirmed, it is not allowed to change the ordered plan or refund.
- Appointment is required for eye examination and hearing assessment. If rescheduling is needed, minimum 24 hours advance notice is required (excluding public holidays as observed in Hong Kong). Optical 88 Ltd. reserves the right to refuse rescheduling within 24 hours and the e-redemption letter will be treated as redeemed.
- This e-redemption letter and identity card shall be presented prior to the hearing assessment on the appointment day.
- In the event of any disputes, the decision of Optical 88 Ltd. and health.ESDlife shall be final.
Guidelines for patients under 18 years old
- All children under age of 16 must be accompanied by a parent or legal guardian
- For children aged 16 -17, if neither parent nor legal guardian is accompanying the youth, advance notice on the contact information of parent or legal guardian is required.
Validity
- The redemption will be valid for 3 months starting from the date of payment.
Eye examination report
- Under normal circumstances, eye examination reports will be ready around 10 working days (excluding Saturday, Sunday and public holidays). Customers can collect the report in any appointed Professional Eyecare Centre or Optical 88 store.
- Customers should authorize a nominee to collect the eye examination report on their behalf. Authorization letter, ID card copy and signature of the nominee are required for collecting report.
Remarks for eye examination report
- All eye examination reports will be destroyed after 12 months if it is not collected
- Customers should keep their reports properly. An administration fee will be charged ($100 per report) for re-issue of the report.
Hearing test result explanation
- Hearing test results will be explained during the appointment. Our professionals or audiologist will recommend appropriate solutions according to every individual’s needs and preferences. No report will be provided.
Disclaimers:
- All health check/health screening services are not for the purpose of medical diagnostic or therapeutic purposes. When there is any sign of symptom/disease in your health, please consult Doctor immediately for diagnosis and treatment.
- The Merchant is the service provider of this Service/Product. ESD Services Limited (“Health.ESDlife”) is not the service provider of this Service/Product. Health.ESDlife is irresponsible to any loss, injury or law action caused by using this service/product. Any claims and inquiries should be addressed to the respective Merchant.